FlowGate2™ 

Balloon Guide Catheter

Track high, protect well.

 

The FlowGate2 Balloon Guide Catheter is designed for rapid access and reliable proximal flow control.

  

Features and benefits

Designed for success

FlowGate2

1. Proximal flow control
with a 10 mm compliant balloon

2. Rapid neurovascular access
with a balance of proximal support and distal flexibility

3. Optimized for clot capture and compatibility
with AXS Catalyst Distal Access Catheters thanks to 8F outer diameter and .084in inner diameter

4. Improved stability
with stainless steel double braid and five transition zones for proximal support and distal flexibility

  

  


Specifications

FlowGate2 Balloon Guide Catheter

FlowGate2 Balloon Guide Catheter

Balloon inflation volume Balloon diameter Balloon length
0.2mL 7mm 8mm
0.4mL 9mm 9mm
0.6mL 10mm 10mm
Guide-assist catheter (dialator)

Guide-assist catheter (dialator)

Tip shape Outer diameter Inner diameter Effective length
Berenstein tip 6F Proximal: 0.053in/
Distal: 0.043in
124cm

*3-way stopcock and syringes (1mL, 20mL, 60mL) are not included, but recommended.

  

Reference number Outer diameter Inner diameter Length
90495 8F (0.106in/2.7mm) 0.084in (6.4F/2.1mm) 95cm
90485 8F (0.106in/2.7mm) 0.084in (6.4F/2.1mm) 85cm

Important safety information

 

 


Learn more about
Stryker Neurovascular's product portfolio

  


  

Contact us

 

 

This information is intended solely for the use of healthcare professionals.

A physician must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that physicians be trained in the use of any particular product before using it in a procedure. The information presented is intended to demonstrate the breadth of Stryker product offerings. A physician must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.

Stryker or its affiliated entities own, use, or have applied for the following trademarks or service marks: FlowGate² Balloon Guide Catheter. All other trademarks are trademarks of their respective owners or holders.

The absence of a product, feature, or service name, or logo from this list does not constitute a waiver of Stryker’s trademark or other intellectual property rights concerning that name or logo.

AP004367 v1.0
Copyright © 2024 Stryker